Evaluation of Different Methods for Hygienic Microbiological Control from the Working Surfaces in the Microbiological Laboratories

Authors

  • Katja Popovska nstitute for Microbiology and Parasitology, Faculty of Medicine, University "Ss Cyril and Methodius", Skopje
  • Milka Zdravkovska Institute for Epidemiology and Biostatistics, Faculty of Medicine, University "Ss Cyril and Methodius", Skopje
  • Vesna Gerasimovska University Clinic for Nephrology, Faculty of Medicine, University "Ss Cyril and Methodius", Skopje
  • Kiril Mihajlov nstitute for Microbiology and Parasitology, Faculty of Medicine, University "Ss Cyril and Methodius", Skopje
  • Bozhica Blazevska nstitute for Microbiology and Parasitology, Faculty of Medicine, University "Ss Cyril and Methodius", Skopje
  • Konstantin Icev nstitute for Microbiology and Parasitology, Faculty of Medicine, University "Ss Cyril and Methodius", Skopje

Keywords:

Environmenth, biomase, plating methods, cultivating methods, hygienic control

Abstract

Background: The role of the inter-hospital non-living environment in spreading of some infections is not universally accepted attitude, but still there is a proof that in some cases it is a risk factor for causing infections with some pathogenic microorganisms. Isolation of microorganisms from the non-living environment can significantly vary in reproducibility and sensitivity of different methods of collecting specimen and its cultivation.

Aim: In aim to develop and assess hygienic control strategies with incorporating better monitoring and improved cleaning, we have undertaken this survey in microbiological labs to offer better approach in infection control procedures for sampling specimens from inanimate environment in health care facilities.

Material and Methods: Three issues might have influence on isolation rates of the mircroorganisms: sampling technique, cultivation methods and professional behaviour of the staff regarding the recommendations and guidelines for hygiene of the workplace. Staphylococcus aureus was almost the only isolated opportunistic microorganism from the surfaces of the workplaces (five from ten), beside Enterococcus, and there was no obvious differentiation in isolation capability between both used swabs. Semi-quantitative method was used for cultivation of saprophytic bacteria. Average of cfu from all used nutrient media was used to estimate bio-mass. out.

Results: Mann-Whitney U test has confirmed statistically significant differentiation between average of cfu (colony-forming unit) (p = 0.0215) sampled with Quanti swab in comparison with wet traditional cotton swab. Plating with swab on trypticase soy agar showed a statistically significant difference between the number of cfu after 24 h and 48 h (Wilcoxon Matched Pairs Test: Z = 2.66; p = 0.0076). Plating with pouring on trypticase soy agar at 450C revealed a statistically significant difference between the number of cfu after 24h and 48 h (Wilcoxon Matched Pairs Test: Z = 2.52; p = 0.01171).

Conlusion: This survey suggests that pour plate method is a more sensitive and appropriate cultivation method for hygienic control in healthcare facilities.

Downloads

Download data is not yet available.

References

Lewis T, Griffith C, Gallo M, Weinbern M. A modified ATP benchmark for evaluating the cleaning of some hospital environmental surfaces. J Hops Infect. 2008;69:156-163. [Web of Science]

Boyce JM, Causey WA. Increasing occurrence methicillin-resistant Staphylococcus aureus in the United States. Infect Control. 1982;3:377-383.

Voss A, Milatovic D, Walrauch-Schwrch C, Rosdahl VT, Braveni I. Methicillin resistant Staphylococcus aureus in Europe. Eur J Clin Microbiol. 1994;13:50-55. [CrossRef]

Talon D. The role of hospital environment in the epidemiology of multi-resistant bacteria. J Hosp Infect. 1999;43:13-17. [CrossRef] [PubMed]

Rampling A, Wiseman S, Davis L, et al. Evidence that hospital hygiene is important in the control of methicillin - resistant Staphylococcus aureus. J Hosp Infect. 2001;49:109-116. [CrossRef]

Obee P, Griffith CJ, Cooper RA, Bennion NE. An evaluation of different methods for the recovery of methicilin-resistant Staphylococcus aureus from environmental surfaces. J Hosp Infect. 2007;65:35-41. [CrossRef] [Web of Science]

Ayliffe GA, Buckles A, Caswell MW, et al. Revised guidelines for the control of methicillin-resistant Staphylococcus aureus infection in hospitals. J Hosp Infect. 1998;39:253-290. [CrossRef]

Frank U. Prevention and control of methicillin-resistant Staphylococcus aureus (MRSA) In: Holland : Fluit AC, Schmitz FJ, editors. MRSA: current perspectives. Witshire: Cromwell Press limited, 2003:317-336.

Moore G, Grifith CJ. A comparison of surface sampling methods for detecting coli forms on food contact surfaces. Food Microbiol. 2002;19:1466-1471.

Scherlock O, O'Connell N, Creamer E, Humphreys H. Is it rely clean? An evaluation of the efficacy of four methods for determining hospital cleanliness. J Hops Infect. 2009;72:140-146.

Perry WD, Siegel AC, Rammelkamp CH Jr, Wannamaker LW, Marple EC. Transmission of group A streptococci. I. The role of contaminated bedding. Am J Hyg. 1957;66(1):85-95.

Perry WD, Siegel AC, Rammelkamp CH Jr. Transmission of group A streptococci. II. The role of contaminated dust. Am J Hyg. 1957;66(1):96-101.

Downloads

Published

2011-09-30

How to Cite

Popovska, K., Zdravkovska, M., Gerasimovska, V., Mihajlov, K., Blazevska, B., & Icev, K. (2011). Evaluation of Different Methods for Hygienic Microbiological Control from the Working Surfaces in the Microbiological Laboratories. Macedonian Journal of Medical Sciences (Archived), 4(3), 240–244. Retrieved from https://journals.mk/index.php/mjms/article/view/MJMS.1857-5773.2011.0183

Issue

Section

Basic Science